Victron Energy Phoenix Smart IP43 Charger
Victron Energy Phoenix Smart IP43 Charger
Phoenix
Smart IP43 charger
Ready for
Bluetooth Smart
Changing the settings
and updating the charger when new ones become available
Software functions can be
any Bluetooth-enabled smartphone, tablet or other device
become.
Phoenix Smart (1+1): two
Outputs for charging two battery banks
The second output is for charging
of the starter battery. Consequently, it is limited to 3 A and has a
something
lower output voltage for
Maintaining the charge of the usually full starter battery.
Phoenix Smart (3): three full
Power outputs for charging 3 battery banks
Each output can have the full
However, all 3 output currents together must not exceed the
Rated current of the charger
not exceed.
Automatic
Voltage compensation
The charger compensates
a voltage drop on the DC cables by reducing the output voltage
slightly increased if the
DC current increases. For more details, see the manual.
Adaptive five-stage
Charging algorithm: constant current (“bulk”) phase, constant voltage (“absorption”)
Phase,
Recovery
(“recondition”) phase, charging float voltage (“float”) phase,
Storage phase
The Phoenix Smart Charger has
about our well-known “adaptive” battery management system, which
on the different
“Adaptive” means that the charging characteristic
automatically
the type of battery use
is adjusted.
The right
Charging quantity: variable constant voltage phase
With low battery discharge
(e.g. a yacht connected to shore power) a short
Constant voltage phase selected to
to avoid overcharging. After a deep discharge, the
Constant voltage phase automatically
extended to ensure that the battery is fully charged.
Prevention of damage caused by
excessive gassing: BatterySafe mode
To shorten the loading time,
The highest possible charging current was combined with a high constant voltage
selected. But in order to
excessive gas development is avoided towards the end of the constant current phase,
The charger limits the
Rate of voltage rise after the gassing voltage is reached
(See charging curve between
14.4 V and 15.0 V in Figure 2.)
Less maintenance and aging in
Battery sleep mode: storage mode
The storage mode is always
activated if no discharge has occurred within 24 hours. In
Storage mode is the
Float charge voltage then to 2.2 V/cell (13.2 V for a 24 V battery)
reduced to
a gas evolution and a
To minimize corrosion on the positive plates, the
Tension to the level of
Gassing voltage is increased. This creates a kind of equalizing charge that
Electrolyte stratification and the
Sulfation - the two main reasons for premature battery failure -
prevented.
Also loads
Lithium-ion (LiFePO₄ ) batteries
It is possible to
On/Off control by connecting a relay or optocoupler output with
open
Collector from a Li-Ion BMS to
remote on/off port.
Alternatively, voltage
and power can also be controlled entirely via Bluetooth.
Fully programmable
Loading algorithm
The charging algorithm can be
Bluetooth or program via the VE.Direct interface.
The MODE button can be used to switch between
three pre-programmed algorithms can be selected (see Technical
Declarations).
Remote On/Off
The remote on/off consists of
two terminals: Remote H and Remote L.
Between H and L a
Remote on/off switch or relay contact can be connected.
Alternatively, Terminal H
be pulled up, or terminal L can be pulled down.
See manual for details.
VE.Direct interface
For a wired
Data connection with a Color Control panel, a PC or other devices.
Please note the
VictronConnect app under Downloads/Software on our website.
Programmable relay
Can be accessed via the
VE.Direct interface or a Bluetooth-enabled device can be programmed,
to set off an alarm or other
to trigger events.